SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-29
Example 9-cylinder Radial (Using Dual SV-EMS-220s,
100399-000, 100399-001, 100399-002 Harnesses)
PRIMARY EMS MODULE with100399-000 Harness
EMS 37-pin Harness
Wire Color
Sensor (with Dynon part number if
applicable)
Battery Voltage (Voltmeter Input)
Elevator Position Potentiometer
150 PSI Oil Pressure (101693-000)
Oil Temperature (100409-000)
15 PSI Fuel Pressure (101690-000) or
50 PSI Fuel Pressure (101716-000)
Heated Pitot Status (Contact Input)
Fuel Flow Power (100403-003)
Manifold Pressure Sensor Power (+5 Volt) and
Kavlico Pressure Sensors (+5 Volt)
Fuel Level Left (Resistive)
Fuel Level Right (Resistive)
Flaps position Potentiometer
Ammeter Shunt + (100412-000)
Ammeter Shunt – (100412-000)
Manifold Pressure (100434-000)
Optional External Alarm Light