VAL Avionics NAV 2000 Przewodnik Instalacji Strona 146

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 145
SV-EMS-220/221 Installation and Configuration
7-38 SkyView System Installation Guide - Revision R
Trigger Coil (Rotax 912, except 912 iS)
The Rotax 912 engines have a 5
th
trigger coil for the purposes of electrically monitoring rev
counts. This trigger coil outputs to a two-wire harness. Connect either of the two wires to
ground; connect the other white wire to SV-EMS-220 Pin 32 (Standard RPM Left Input). If you
observe erratic tachometer readings or momentary “spikes” in the display - particularly at
higher RPM install a 60K resistor inline (in series) between the trigger coil and SV-EMS-220 Pin
32, White/Green wire). Set Pulses / Revolution (PPR) to 1: SETUP MENU > HARDWARE
CALIBRATION > EMS CALIBRATION > TACHOMETER CALIBRATION > PUL/REV (C37 P32/34)
Rotax 914
The Rotax 914 uses a Turbo Control Unit (TCU), which provides an RPM output < 10V.
Connect Pin 13 of the TCU to SV-EMS-220 Pin 34 (Low Voltage RPM Left Input).
Connect Pin 26 of the TCU to any of Pins 3, 5, 13, 16, 17, or 30 (Ground).
Do not install a resistor in the wires between the TCU and the SV-EMS-220.
Set Pulses / Revolution (PPR) to SETUP MENU > HARDWARE CALIBRATION > EMS CALIBRATION
> TACHOMETER CALIBRATION > PUL/REV (C37 P32/34)
Alternator Wire (Jabiru)
The most common tachometer pickoff location for Jabiru 2200 and 3300 engines is one of the
alternator wires. Connect one of the two white alternator wires through a 1 amp fuse to SV-
EMS-220 Pin 32 (Standard RPM Left Input). Set Pulses / Revolution (PPR):
Jabiru 22000A 5
Jabiru 3300 w/3-phase alternator 4
Jabiru 3300 w/single-phase 6
SETUP MENU > HARDWARE CALIBRATION > EMS CALIBRATION > TACHOMETER CALIBRATION >
PUL/REV (C37 P32/34)
Other Ignition Systems
The SV-EMS-220/221’s Standard Voltage RPM inputs can read frequency-based RPM signals,
provided the peak voltages goes at least 5.1 volts above ground, and crosses back down below
2.0V relative to ground. If the peak voltage exceeds 50 volts, use the included 30 k resistors as
described in the P-lead pickoff (Lycoming and Continental) Section above.